Fire hydrants
Valves, hoses, nozzles, cabinets, pumps and inlets — everything a wet-riser or yard hydrant system needs, supplied and installed to IS standards.
Enquire on WhatsApp
Fire hydrant valve — single controlGunmetal landing valve with one 63 mm instantaneous outlet, for internal and yard hydrants. IS 5290.Learn more
Branch pipe & nozzleGunmetal or aluminium branch pipe with a fixed nozzle, the standard end of every hose line.Learn more
Short branch pipe nozzleCompact branch pipe for hose-reel and first-aid lines where a long branch is awkward to handle.Learn more
Long branch pipe nozzleFull-length branch pipe for a longer, steadier jet from a 63 mm delivery hose.Learn more
RRL hose pipe / fire hose pipeReinforced rubber-lined 63 mm delivery hose in 15 m and 30 m lengths, with male/female couplings bound on. IS 636 type A and B.Learn more
First aid hose reelWall-mounted 19 mm or 25 mm hose reel with 30 m of hose and a shut-off nozzle, for first attack by anyone in the building.Learn more
Swinging type wall-mounted hose reel drumA hose reel on a swing arm that turns through 180°, so the hose pulls straight off in any direction.Learn more
2 way / 4 way inlet breechingFire-service inlet in two- or four-way form, so the brigade can feed the riser or sprinkler main from its appliance.Learn more
2-way inlet breechingFire-service inlet with two 63 mm instantaneous connections, for risers in low-rise buildings.Learn more
3-way inlet breechingThree-inlet fire-service connection for larger risers and sprinkler mains.Learn more
4-way inlet breechingFour-inlet fire-service connection for high-rise wet risers and large sprinkler installations.Learn more
Fire hose cabinetFRP or mild-steel cabinet holding the hose, branch and hydrant valve at each landing. Glass front, keyed or break-glass.Learn more
Water jet monitorA fixed or portable monitor that throws a large jet a long way, for yards, tank farms and warehouses.Learn more- Fire hydrant valve — double controlTwin-outlet landing valve so two hose lines run from one hydrant point. Gunmetal, IS 5290.Learn more
- Triple purpose branch pipeJet, spray and shut-off in one branch — the operator changes the pattern at the nozzle.Learn more
- Navy diffuser branch pipeProduces a fine spray for cooling and for pushing back heat, as used on ships and in plant rooms.Learn more
- Fog nozzle branch pipeAdjustable fog pattern for fighting liquid fires and shielding the firefighter from radiant heat.Learn more
- Revolving branch pipeA rotating head that throws water in a wide pattern, for cooling ducts, cable galleries and basements.Learn more
- Curtain nozzleLays a flat sheet of water to stop fire spreading across an opening or between adjacent risks.Learn more
- Hose reel with foam tankA hose reel with its own foam concentrate tank and inductor, for liquid-fuel risks where water alone will not do.Learn more
- Combo cabinetOne cabinet for the hose reel, the delivery hoses and the branch pipes together — tidier on a landing and quicker to find.Learn more
- Diesel engine driven pumpThe standby fire pump that runs when the power fails — sized to the hydrant and sprinkler demand of the site.Learn more
- Main pumpElectric main fire pump for the hydrant and sprinkler system, with the flow and head the system design calls for.Learn more
- Jockey & booster pumpSmall pumps that hold the system at pressure and make up for leakage, so the main pump starts only for a real demand.Learn more
- Jockey pump with controllerA jockey pump supplied with its own pressure-switch controller, ready to wire into the pump house.Learn more
- Electric motor driven pumpsetPump, motor and base plate as one assembled set, for hydrant, sprinkler and booster duty.Learn more
- Engine drive split case pumpsetHorizontal split-case pump on a diesel engine for high flows — large factories, refineries and tank farms.Learn more
- Impactur mobile fire pumpA self-start engine-driven pump on wheels with 30 m of hose and a 40-litre foam tank: 250 litres a minute, a 35 m throw, for sites with no hydrant main.Learn more
- Fire pump control panelAutomatic starter panel for the main, jockey and diesel pumps, with pressure switches, indications and manual override.Learn more
- Fire hose delivery coupling63 mm instantaneous male and female couplings in gunmetal or stainless steel, for binding onto delivery hose. IS 903.Learn more
- 2-way stand post hydrantYard hydrant on a stand post with two landing valves, for external hydrant rings.Learn more
- 4-way stand post hydrantFour-outlet yard hydrant for large plants where several lines run from one point.Learn more
- 2-way stand post with monitor hydrantA stand post carrying two landing valves and a water monitor on top, for tank farms and open yards.Learn more
- Underground fire hydrantA hydrant below ground level under a surface box, where an above-ground post would be in the way of traffic.Learn more
- Surface boxCast-iron cover and frame over an underground hydrant or sluice valve, marked and set flush with the ground.Learn more
- PVC nozzleLight PVC shut-off nozzle for 19 mm and 25 mm hose reels.Learn more
- Gunmetal nozzleHeavy-duty gunmetal hose-reel nozzle with jet and spray, for industrial use.Learn more
- PVC hoseFlexible PVC hose for hose reels and first-aid lines, in 19 mm and 25 mm.Learn more
- Rubber hoseThermoplastic rubber hose-reel hose that stays supple in heat and sun, for outdoor and industrial reels.Learn more
- Premier hoseControlled-percolating delivery hose for hydrant lines where the hose itself must stay cool.Learn more
- Premier extra hoseA heavier-duty grade of percolating hose with a thicker jacket for rough ground and longer life.Learn more
- Butterfly valveIsolating valve for hydrant and sprinkler mains, with a supervised position indicator where the design needs it.Learn more
- FRP tankFibre-reinforced plastic storage tank for fire-water and foam concentrate, in standard and custom capacities.Learn more